Load cell/weighing modular
High-Grade Materials, Reliable Accuracy.
ViPOO Sensors: Crafted with Premium Materials for Unshakable Stability and Unmatched Precision.
SL-RC3 Compression load cell

Single column compression load cell – the SL-RC3. Compact and yet very robust the SL-RC3 is available in a very wide range of capacities from 7.5t through to 100t. The rocker column design ensures that the optimum weighing accuracy is achieved when subjected to scale deck movement. Fully hermetically sealed and constructed from stainless steel the SL-RC3 is a more economical solution to the RC1 load cell.

Product description

Single column compression load cell – the SL-RC3. Compact and yet very robust the SL-RC3 is available in a very wide range of capacities from 7.5t through to 100t. The rocker column design ensures that the optimum weighing accuracy is achieved when subjected to scale deck movement. Fully hermetically sealed and constructed from stainless steel the SL-RC3 is a more economical solution to the RC1 load cell.

Applications

Truck scales, railroad scales, high capacity scales, silo weighing systems.

Key features

All stainless-steel construction

Hermetically sealed to IP68
Self-restoring column design
Wide range of capacities from 7.5t through to 100t
High input resistance
Calibration in mV/V/Ω

Product dimensions (mm)

110.jpg

MRD* - Mandatory main rocking direction
Top* - Top view

Wiring

The load cell is provided with a shielded, 4 conductor cable (7.5 to 22.5t: AWG 24; 30t + 40t: AWG 20 or AWG 24; 50 t or higher: AWG 20).

Cable jacket: polyurethane
Cable length: 12m for 7.5 to 22,5 t
18m for 30 to 300 t / on request various length available
Cable diameter: 5 mm for 7.5 to 22.5 t (30 t and 40 t as an option)
7.8 mm for 30 to 300 t
The shield is floating (On request the shield can be connected to the load cell body)

110.jpg

Available models

-

SL-RC3 / SL-RC3-TS

Accuracy class according to OIML R60

-

(GP)

C3

C3

C3 MI7

C4

Available maximum capacities (E max)

t

7.5 / 15 /

22.5 / 30 /

40 / 50 /

100

7.5 / 15 /

22.5

30 / 40 / 50

30 / 40 / 50

30 / 40 / 50

Maximum number of verification intervals (nLC)

-

n.a.

3500

3000

3000

4000

Minimum load cell verification interval (vmin)

-

n.a.

Emax / 10000

E max / 15000

Emax / 15000

E max / 15000

Temp. effect on minimum dead load output (TC0)

%*RO/10°C

± 0.0400

± 0.014

± 0.0093

± 0.0093

± 0.0093

Temperature effect on sensitivity (TCRO)**

%*RO/10°C

± 0.0200

± 0.01

± 0.01

± 0.01

± 0.008

Combined error***

%*RO

± 0.0500

± 0.02

± 0.02

± 0.018

± 0.018

Non-linearity**

%*RO

± 0.0400

± 0.0166

± 0.0166

± 0.0166

± 0.0125

Hysteresis**

%*RO

± 0.0400

± 0.0166

± 0.0166

± 0.010

± 0.0125

Creep error (30 minutes) / DR

%*RO

± 0.0600

± 0.0166

± 0.0166

± 0.0070

± 0.0125

Minimum dead load (Emin)


0%*Emax

Rated Output (RO)

mV/V

2 ± 0.1%

Calibration in mV/V/Ω (A...I classified)

%

± 0.05 (± 0.005)

Zero balance

%*RO

± 5

Excitation voltage

V

5...15

Input resistance (RLC)

Ω

1,150 ± 50

Output resistance (Rout)

Ω

1,000 ± 2

Insulation resistance (100 V DC)

≥ 5,000

Safe load limit (Elim)

%*E max

200

Ultimate load

%*E max

300

Compensated temperature range

°C

–10...+40

Operating temperature range

°C

–40...+80 (ATEX –40...+60)

Load cell material


stainless steel 17-4 PH (1.4548)

Sealing


complete hermetic sealing; cable entry sealed by glass to metal header

Protection according EN 60 529


IP68 (up to 2m water depth) / IP69K

Packet weight

kg

1.3 (7.5t), 1.4 (15t), 1.5 (22.5t), 3.4 (30t), 3.6 (40t), 4.5 (50t), 12.9 (100t), 17.1