SL-RC3 Compression load cell
Single column compression load cell – the SL-RC3. Compact and yet very robust the SL-RC3 is available in a very wide range of capacities from 7.5t through to 100t. The rocker column design ensures that the optimum weighing accuracy is achieved when subjected to scale deck movement. Fully hermetically sealed and constructed from stainless steel the SL-RC3 is a more economical solution to the RC1 load cell.
Product description
Single column compression load cell – the SL-RC3. Compact and yet very robust the SL-RC3 is available in a very wide range of capacities from 7.5t through to 100t. The rocker column design ensures that the optimum weighing accuracy is achieved when subjected to scale deck movement. Fully hermetically sealed and constructed from stainless steel the SL-RC3 is a more economical solution to the RC1 load cell.
Applications
Truck scales, railroad scales, high capacity scales, silo weighing systems.
Key features
All stainless-steel construction
| Hermetically sealed to IP68 |
| Self-restoring column design |
| Wide range of capacities from 7.5t through to 100t |
| High input resistance |
| Calibration in mV/V/Ω |
Product dimensions (mm)

MRD* - Mandatory main rocking direction
Top* - Top view
Wiring
The load cell is provided with a shielded, 4 conductor cable (7.5 to 22.5t: AWG 24; 30t + 40t: AWG 20 or AWG 24; 50 t or higher: AWG 20).
| Cable jacket: polyurethane |
| Cable length: 12m for 7.5 to 22,5 t |
| 18m for 30 to 300 t / on request various length available |
| Cable diameter: 5 mm for 7.5 to 22.5 t (30 t and 40 t as an option) |
| 7.8 mm for 30 to 300 t |
| The shield is floating (On request the shield can be connected to the load cell body) |

Available models | - | SL-RC3 / SL-RC3-TS | ||||
Accuracy class according to OIML R60 | - | (GP) | C3 | C3 | C3 MI7 | C4 |
Available maximum capacities (E max) | t | 7.5 / 15 / 22.5 / 30 / 40 / 50 / 100 | 7.5 / 15 / 22.5 | 30 / 40 / 50 | 30 / 40 / 50 | 30 / 40 / 50 |
Maximum number of verification intervals (nLC) | - | n.a. | 3500 | 3000 | 3000 | 4000 |
Minimum load cell verification interval (vmin) | - | n.a. | Emax / 10000 | E max / 15000 | Emax / 15000 | E max / 15000 |
Temp. effect on minimum dead load output (TC0) | %*RO/10°C | ± 0.0400 | ± 0.014 | ± 0.0093 | ± 0.0093 | ± 0.0093 |
Temperature effect on sensitivity (TCRO)** | %*RO/10°C | ± 0.0200 | ± 0.01 | ± 0.01 | ± 0.01 | ± 0.008 |
Combined error*** | %*RO | ± 0.0500 | ± 0.02 | ± 0.02 | ± 0.018 | ± 0.018 |
Non-linearity** | %*RO | ± 0.0400 | ± 0.0166 | ± 0.0166 | ± 0.0166 | ± 0.0125 |
Hysteresis** | %*RO | ± 0.0400 | ± 0.0166 | ± 0.0166 | ± 0.010 | ± 0.0125 |
Creep error (30 minutes) / DR | %*RO | ± 0.0600 | ± 0.0166 | ± 0.0166 | ± 0.0070 | ± 0.0125 |
Minimum dead load (Emin) | 0%*Emax | |||||
Rated Output (RO) | mV/V | 2 ± 0.1% | ||||
Calibration in mV/V/Ω (A...I classified) | % | ± 0.05 (± 0.005) | ||||
Zero balance | %*RO | ± 5 | ||||
Excitation voltage | V | 5...15 | ||||
Input resistance (RLC) | Ω | 1,150 ± 50 | ||||
Output resistance (Rout) | Ω | 1,000 ± 2 | ||||
Insulation resistance (100 V DC) | MΩ | ≥ 5,000 | ||||
Safe load limit (Elim) | %*E max | 200 | ||||
Ultimate load | %*E max | 300 | ||||
Compensated temperature range | °C | –10...+40 | ||||
Operating temperature range | °C | –40...+80 (ATEX –40...+60) | ||||
Load cell material | stainless steel 17-4 PH (1.4548) | |||||
Sealing | complete hermetic sealing; cable entry sealed by glass to metal header | |||||
Protection according EN 60 529 | IP68 (up to 2m water depth) / IP69K | |||||
Packet weight | kg | 1.3 (7.5t), 1.4 (15t), 1.5 (22.5t), 3.4 (30t), 3.6 (40t), 4.5 (50t), 12.9 (100t), 17.1 (150t), 32.8 (300t) | ||||