载荷传感器/称重传感器
精选优质材料,确保精准可靠。
ViPOO传感器:采用高性能材料打造,实现稳定持久的测量性能与精确的计量表现。
SL-RC3D Column Digital Load Cell

The digital SL-RC3D compression load cell features embedded electronics that improve system accuracy and load cell handling and allows the user to communicate with each load cell independently. It’s designed so that multiple  cells can be wired together in a daisy chain to the indicator, greatly simplifying installations by avoiding the need for a junction box.

Product description

The digital SL-RC3D compression load cell features embedded electronics that improve system accuracy and load cell handling and allows the user to communicate with each load cell independently. It’s designed so that multiple cells can be wired together in a daisy chain to the indicator, greatly simplifying installations by avoiding the need for a junction box.

The SL-RC3D is compact and robust, built from high-grade stainless steel and fully hermetically sealed; its performance can be relied upon in even the harshest of conditions. A rocker column design helps ensure optimum weighing accuracy when subjected to off-centre forces from scale deck movements.

The SL-RC3D can be provided with either the standard connectors or cabled connectors. The cabled variant is detailed at the end of this datasheet.

Applications

Weighbridges, hoppers, tanks and silos.

Accessories + Options

Standard connectors or cabled connectors available
Range of hardware and electronics

Maximum Capacity (E max)

t

30/40/50

Accuracy class according to OIML R60


(GP)

C1

C3

C4

Maximum number of verification intervals (nLC)


n.a.

1,000

3,000

4,000

Minimum load cell verification interval (vmin )


n.a.

E max /5,000

E max /15,000

Temperature effect on minimum dead load output (TC0)

%*RO/10°C

± 0.0400

± 0.0280

± 0.0093

Temperature effect on sensitivity (TCRO)

%*RO/10°C

± 0.0200

± 0.0160

± 0.0100

± 0.0080

Combined error

%*RO

± 0.0500

± 0.0300

± 0.0200

± 0.0180

Non-linearity

%*RO

± 0.0400

± 0.0300

± 0.0166

± 0.0125

Hysteresis

%*RO

± 0.0400

± 0.0300

± 0.0166

± 0.0125

Creep error (30 minutes) / DR

%*RO

± 0.0600

± 0.0490

± 0.0166

± 0.0125

Rated Output (RO)

counts

200,000 ± 200 (± 0.1%*RO)

Zero balance

counts

± 2,000 (± 1%*RO)

Internal resolution

counts

500,000

Excitation voltage

V

10...12

Current consumption

mA

< 40

Converter type


Sigma-Delta ratiometric

Conversion rate


10 Hz (4.7 to 80 Hertz, factory configuration only)

Digital filter


Rolling Average (4, 9, 16, 25 samples)

Asynchronous interface


RS485A half duplex, multidrop with network address, 2,400...38,400 baud. Baudrate, data bits, parity and data output are programmable

Number of bus addresses

n

52

Safe load limit (Elim)

%*E max

200

Ultimate load

%*E max

300

Compensated temperature range

°C

–10...+40

Operating temperature range

°C

–40...+60

Load cell material


stainless steel 17-4 PH (1.4548)

Sealing


complete hermetic sealing; cable entry sealed by glass to metal header

Protection according EN 60 529


IP68 (up to 2m water depth) / IP69K

Packet weight

kg

3.3 (30t), 3.6 (40t), 4.5 (50t)

Load cell cable length

-

Standard: 10m - supplied with 2x M12 right-angle, female connectors Cabled var: 2x 1m with M12 female, attached via cable glands

Load cell connectors