SL-RC3D Column Digital Load Cell
The digital SL-RC3D compression load cell features embedded electronics that improve system accuracy and load cell handling and allows the user to communicate with each load cell independently. It’s designed so that multiple cells can be wired together in a daisy chain to the indicator, greatly simplifying installations by avoiding the need for a junction box.
Product description
The digital SL-RC3D compression load cell features embedded electronics that improve system accuracy and load cell handling and allows the user to communicate with each load cell independently. It’s designed so that multiple cells can be wired together in a daisy chain to the indicator, greatly simplifying installations by avoiding the need for a junction box.
The SL-RC3D is compact and robust, built from high-grade stainless steel and fully hermetically sealed; its performance can be relied upon in even the harshest of conditions. A rocker column design helps ensure optimum weighing accuracy when subjected to off-centre forces from scale deck movements.
The SL-RC3D can be provided with either the standard connectors or cabled connectors. The cabled variant is detailed at the end of this datasheet.
Applications
Weighbridges, hoppers, tanks and silos.
Accessories + Options
Standard connectors or cabled connectors available
Range of hardware and electronics
Maximum Capacity (E max) | t | 30/40/50 | |||
Accuracy class according to OIML R60 | (GP) | C1 | C3 | C4 | |
Maximum number of verification intervals (nLC) | n.a. | 1,000 | 3,000 | 4,000 | |
Minimum load cell verification interval (vmin ) | n.a. | E max /5,000 | E max /15,000 | ||
Temperature effect on minimum dead load output (TC0) | %*RO/10°C | ± 0.0400 | ± 0.0280 | ± 0.0093 | |
Temperature effect on sensitivity (TCRO) | %*RO/10°C | ± 0.0200 | ± 0.0160 | ± 0.0100 | ± 0.0080 |
Combined error | %*RO | ± 0.0500 | ± 0.0300 | ± 0.0200 | ± 0.0180 |
Non-linearity | %*RO | ± 0.0400 | ± 0.0300 | ± 0.0166 | ± 0.0125 |
Hysteresis | %*RO | ± 0.0400 | ± 0.0300 | ± 0.0166 | ± 0.0125 |
Creep error (30 minutes) / DR | %*RO | ± 0.0600 | ± 0.0490 | ± 0.0166 | ± 0.0125 |
Rated Output (RO) | counts | 200,000 ± 200 (± 0.1%*RO) | |||
Zero balance | counts | ± 2,000 (± 1%*RO) | |||
Internal resolution | counts | 500,000 | |||
Excitation voltage | V | 10...12 | |||
Current consumption | mA | < 40 | |||
Converter type | Sigma-Delta ratiometric | ||||
Conversion rate | 10 Hz (4.7 to 80 Hertz, factory configuration only) | ||||
Digital filter | Rolling Average (4, 9, 16, 25 samples) | ||||
Asynchronous interface | RS485A half duplex, multidrop with network address, 2,400...38,400 baud. Baudrate, data bits, parity and data output are programmable | ||||
Number of bus addresses | n | 52 | |||
Safe load limit (Elim) | %*E max | 200 | |||
Ultimate load | %*E max | 300 | |||
Compensated temperature range | °C | –10...+40 | |||
Operating temperature range | °C | –40...+60 | |||
Load cell material | stainless steel 17-4 PH (1.4548) | ||||
Sealing | complete hermetic sealing; cable entry sealed by glass to metal header | ||||
Protection according EN 60 529 | IP68 (up to 2m water depth) / IP69K | ||||
Packet weight | kg | 3.3 (30t), 3.6 (40t), 4.5 (50t) | |||
Load cell cable length | - | Standard: 10m - supplied with 2x M12 right-angle, female connectors Cabled var: 2x 1m with M12 female, attached via cable glands | |||
Load cell connectors | 2x M12, 4-pin, male | ||||